Advanced inspection of electrical systems using acoustic cameras
Partial discharge (PD) detection is a critical predictive electrical maintenance technique that identifies incipient insulation faults before they develop into electric arcs, short circuits or unplanned shutdowns. In Monterrey and its industrial area, this service is key for plants operating at medium and high voltage, where operational continuity and safety are top priorities.
What are partial discharges?
Partial discharges are localized ionizations that occur at defects in electrical insulation without a complete breakdown. Their presence indicates progressive deterioration of the electrical system and, if not addressed, can lead to:
-
Catastrophic failures
-
Damage to critical equipment
-
Fire hazards
-
Production interruptions
Technology used: Acoustic cameras
Our service uses high-resolution acoustic cameras capable of detecting the ultrasonic emissions generated by partial discharges, even in noisy industrial environments.
Measurement principle
-
Microphone arrays with acoustic beamforming
-
Detection in the ultrasonic range (≈20–80 kHz)
-
Precise spatial location of the discharge source
-
Acoustic map overlaid on the visible image
This makes it possible to identify the exact point of the defect without contact and with the system energized.
Types of detectable partial discharges
-
Corona discharge: on conductors, busbars, points and sharp edges
-
Surface discharge: on contaminated or aged insulators
-
Incipient electric arcs: high-risk early-stage faults
Industrial applications in Monterrey
-
Electrical substations
-
Medium-voltage switchgear
-
Motor control centers (MCC)
-
Overhead lines and busbars
-
Manufacturing, steel, automotive and process plants
Standards and technical references
Our service is aligned with the following international standards and guidelines:
-
IEC 60270 – Partial discharge measurements
-
IEC 62478 – Non-conventional methods for PD detection
-
IEEE 1434 – Guide for PD measurement and diagnosis
-
NFPA 70B – Condition-based electrical maintenance
-
NETA ATS / MTS – Electrical testing and maintenance
Benefits of the service
-
Contactless inspection with no shutdown of operations
-
Early detection of electrical faults
-
Reduced operational and safety risks
-
Clear visual evidence for reports and audits
-
Optimization of maintenance plans
Deliverables
-
Professional technical report
-
Visible images and acoustic maps
-
Discharge severity classification
-
Technical recommendations for corrective action
Partial discharge detection service in Monterrey
We offer specialized partial discharge detection services in Monterrey, focused on industries that require electrical reliability, safety and regulatory compliance.
Contact us for a technical assessment and schedule your advanced electrical inspection.